Feel confident.
Planning, guidance and follow-up of (T)EVAR cases may be delicate when dealing with complex anatomies. Leveraging pre-operative imaging and planning data during the intervention may be difficult. Under 2D fluoroscopic imaging, (T)EVAR procedures can require a significant amount of contrast media, prolonged radiation exposure, and time. A 3D view of vessels anatomy could help you perform complex interventional procedures. Surveillance of the aneurysm sac with reliable measurements can be a challenge.
(T)EVAR Assist1 is an integrated solution to help plan, guided and follow-up (T)EVAR cases:
Plan with VesselIQ Xpress and VVI, the AW CT vascular analysis software that delivers 0-click bone removal and tracking of the aorta as well as key anatomy measurements.
Guide with Innova Vision that overlays 3D datasets from CT, MR or 3D rotational images on live fluoroscopic images in a single click.
Follow-up using semi-automatic sizing of the thrombus and compare mode.
Highlights
Plan on CT Angiography using 0-click Bone Removal and tracking of the aorta.
1-click overlay of 3D CTA prepared data on top of live fluoroscopic images.
Directly register from the control room or at table side CT models with only 2 fluoroscopy views for efficiency in procedure time and dose.
Register in real time to C-arm and table movements, field of view, source-to-image distance.
Semi-automatic sizing of the thrombus.
1. (T)EVAR Assist Solution refers to Volume Viewer Innova, VesselIQ Xpress, Synchro3D and Innova Vision.
1. Planning with VesselIQ Xpress, VVI and Synchro3D
Aorta analysis
Save State
Synchro3D
2. Real-Time 3D guidance with Innova Vision
Multimodality Fusion
Ease of use and enhanced visualization
3. Aneurysm surveillance with VesselIQ Xpress
Aneurysm sac assessment
Multiple Study Comparison
VesselIQ Xpress is a post processing application option for the Advantage Workstation (AW) platform, CT Scanner or PACS stations, which can be used in the analysis of 2D and 3D CT Angiography images/data derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular and vascular disease assessment. This software is designed to support the physician in assessment of vessel analysis, pre/post stent planning and directional vessel tortuosity visualization.
Innova Vision is intended to enable users to load 3D datasets and overlay and register in real time these 3D datasets with fluoroscopic or radiographic images of the same anatomy in order to support catheter/device guidance during interventional procedures.
Volume Viewer, including Volume Viewer Innova and Synchro3D, is medical diagnosis software that allows the processing, review, analysis, and communication of 3D reconstructed images and their relationship with originally acquired images from CT, MR, X-Ray Angiography, and PET scanning devices. The combination of acquired images, reconstructed images, annotations, and measurements performed by clinicians are intended to provide referring physicians with clinically relevant information for diagnosis, surgery, and treatment planning.
Multimodality Synchro3D is a software that allows to align the viewing incidence of the 3D model with the incidence of the X-ray beam on the X-ray gantry. This alignment is intended to:
Multimodality In-Room 3D software and Mouse device (optional device on Innova product) are intended to control the 3D model and the alignment functions from the X-ray table-side, thus optimizing the workflow and ergonomics of the intervention.